Residue Detector for Veterinary Drug with Not Include Pre-Processing Tools

Product Details
Customization: Available
After-sales Service: Lifetime Maintenance
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
65
Year of Establishment
2018-10-08
  • Residue Detector for Veterinary Drug with Not Include Pre-Processing Tools
  • Residue Detector for Veterinary Drug with Not Include Pre-Processing Tools
  • Residue Detector for Veterinary Drug with Not Include Pre-Processing Tools
Find Similar Products
  • Overview
  • Product Description
  • Feature
  • Specification
  • Packing & Delivery
  • After-sale Service
  • FAQ
  • Customer Response
Overview

Basic Info.

Model NO.
TPSY-96
Element
Veterinary Drug Residue Detector
Display
Computer Screen
Application
Veterinary Drug Residue Detector
Frequency
50±1HZ
Performance
Automation
Weight
0-100Kg
Power Source
AC220V±22V
Customized
Customized
Province
Zhejiang
Transport Package
Carton
Trademark
AG
Origin
China
HS Code
90318090
Production Capacity
300 Set/Sets / Week

Product Description

Product Description

Residue Detector for Veterinary Drug with Not Include Pre-Processing Tools
The instrument can quantitatively and qualitatively detect hormones and antibiotic residues in livestock products, aquatic products, and animal diseases. Aquatic product antibiotics: chloramphenicol, streptomycin, sulfonamides, furans, tetracyclines, malachite green, diethylstilbestrol, etc.; livestock product hormones: clenbuterol, ractopamine, salbutamol; grain and oil products: Aflatoxin B1, M1, zearalenone, vomiting toxin; dairy products: antibiotics, melamine, etc.

Feature

•Using 800*480 resolution true color 7-inch LCD touch screen display, windows interface, Chinese man-machine dialogue operation.
•The instrument has a power-on self-check function, and the fault is displayed on the LCD screen in real time.
•Filter conversion method: automatic conversion by the instrument;
•Detection type: single and dual wavelength and single and double hole detection methods are available for selection.
•Layout form: Freely arrange the holes of reference, standard, and sample horizontally or vertically.
•The energy-saving design of the automatic switch of the light source is adopted to extend the life of the light source to the maximum extent. It has the function of self-checking and alarming the optical path and mechanical moving parts to ensure that the instrument is in good working condition.
•The setting of project parameters: 200 test project parameters and 100,000 test data can be set, saved, modified, and inquired about for future testing;
•Detection and calibration: It has the function of detection and calibration, which can save and modify the calibration parameters and curves of 126 items. It can be called and printed when the same item is tested;
•Use the built-in embedded micro thermal printer
•Output: absorbance test, pesticide residue test, veterinary drug residue test (quantitative), qualitative test, a reference value, and quantitative judgment result report, and qualitative analysis of negative and positive judgment results report;
•Support RS232 communication port; support external USB data cable to connect directly with PC; support EXCEL format data export function; support multiple comprehensive report output and summary statistics functions
•Printing: The instrument is equipped with a built-in thermal printer or an external printer, and you can choose to automatically print or manually print the entire page test results.
•Equipped with professional software, the PC can control any work of the instrument, realize real-time data collection, data query, and summary, supplier information management, etc.

•Optical path system: self-calibrating 8-channel optical path system. The standard filters are 405nm, 450nm, 492nm, and 630nm, and up to 10 filters are optional.
•Light source: Quartz halogen lamp is adopted, which will automatically switch to half-pressure sleep mode when there is no operation after the machine is turned on, so as to maximize the life of the light source lamp.
•Difference between channels: The difference in absorbance between channels of the instrument should be ≤0.02A.
•Repeatability ±0.005A (0~2A)
•Stability ≤0.005A/hour
•Stray light: Use 510nm to detect 50.0g/L sodium nitrite standard solution, the absorbance should be ≥2.0A.
Interface mode: RS-232/USB
•Storage: 105 boards, more than 10,000 sets of measurement data
•The instrument has qualitative and quantitative analysis functions and can output the original absorbance report, critical value, P/CO value, concentration data report, and qualitative analysis of negative and positive results.
•Qualitative and quantitative calculation methods: 9 methods including single point method, point-to-point method, linear regression method, semi-log regression, full log regression, ratio regression, ratio semi-log regression, exponential regression, and quadratic curve
•Printing: The instrument is equipped with a built-in thermal printer or an external printer, and you can choose to automatically print or manually print the entire page test results.

Specification

Wavelength range
400-1100nm
Wavelength accuracy
±2.0nm
Half width
8±1.0nm
Measuring range
0.000-4.000Abs
Resolution
0.001A
Accuracy
±1% (0~2A)
Linearity error
±0.1% (0~2A)
Repeatability
±0.005A (0~2A)
Reading speed
5s
Interface mode
RS-232/USB

Packing & Delivery

Residue Detector for Veterinary Drug with Not Include Pre-Processing ToolsResidue Detector for Veterinary Drug with Not Include Pre-Processing Tools

After-sale Service

Residue Detector for Veterinary Drug with Not Include Pre-Processing ToolsWe have a professional after-sales team with global service coverage and a 24-hour time difference free to provide you with solutions.

FAQ

1. Are you a manufacturer or not?
Yes, we are. We have more than 300 workers and 26680 square meters of production base in Zhejiang province which is close to Shanghai and Ningbo port. Welcome to come and visit our factory.


2. How do you guarantee the quality of your products?
We have passed ISO9001 / 14001 / 45001 quality system certification. And has a professional quality inspection team of more than 30 inspectors. Adhere to the strict quality control of each process from raw materials to packaging.

3. What is your after-sales service?
The warranty time is 1 full year, lifelong maintenance.

4. How long is your delivery lead time?
It is generally 3-5 days, but it will vary according to different products and quantities.
 
5. OEM available?
Yes, OEM is acceptable. Please contact us for specific information.

Customer Response

Residue Detector for Veterinary Drug with Not Include Pre-Processing Tools

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier